In the process of using the IMC05, the IMC05 may show an abnormal state and display the error codes on the screen. The description of the error codes and the related handling method is shown in table 2-1.
Notice:
- When the IMC05 reports the following Error Code, the banknote that caused the error will not be counted in the total, and you need to take the wrong one away.
- When the IMC05 reports the Chain note Error, the counting result will be inaccurate, please fine-tune the screw to adjust the feeding gap according to E80 in the following table.
Table 2‑1 Error Codes
Code |
Error Message |
Handling Method (Recommendation) |
E10 |
Fake note detected by UV |
Remove the fake note from the stacker, press “START” to continue |
E72 |
Fake note detected by MG |
Remove the fake note from the stacker, press “START” to continue |
CE0 |
Double note detected by IR |
Remove the double note from the stacker, press “START” to continue |
E80 |
Chain note or different width note detected |
Please refer to the section to fix the E80 error: |
E41 |
Half note detected |
Remove the half note from the stacker, press “START” to continue |
E82 |
DD Error |
Check whether the banknote detector is using the banknote guide plate, then remove the banknote with DD Error, and press the START button to continue |
CE1 |
Problem with the UV sensor |
Clean the sensor or replace it |
CE2 |
Problem with code disc sensor or big motor |
Replace the sensor or big moto |
CE3 |
Problem with left counting sensor |
Clean the sensor or replace it |
CE4 |
Problem with right counting sensor |
Clean the sensor or replace it |
CE5 |
Problem with hopper sensor |
Clean the sensor or replace it |
CE7 |
Problem with MG sensor |
Replace the MG sensor |
CE8 |
Problem with stacker sensor |
Clean the sensor or replace it |